400-600-5039

技术文章

BET 比表面分析测试仪 JW-DA BET Surface Area Analyzer的行业应用@技术新闻

阅读次数:3098次 发布时间:2023/5/15 14:53:34

据技术部5月15日14点11分透露:BET 比表面分析测试仪 JW-DA BET Surface Area Analyzer的行业应用@技术新闻 http://www.app17.com/c151186/products/d9715127.html

比表面及孔径分析仪,物理吸附仪,比表面积测量仪,真密度仪


- -Technical Parameters

Test principal: Continuous Flow Chromatography method, Low temperature nitrogen adsorption

Test methods: Direct Comparison method, BET (single-point, multi-point), Langmuir surface area

Adsorption gas:  N2 (Adsorbate 99.999%, He  (Carrier 99.999%)

Flow control: automatic control program, P / Po 0.05 - 0.35, control accuracy error ≤ 0.5%;

Control efficiency: 0.01 ml / min, each point of P/Po adjustment ≤ 5 seconds

Calibration: the quantitative volume of nitrogen used for calibrating automatically

Measuring range: Surface area ≥ 0.01m2/g, no upper limits;

Sample NO:  4

Test Efficiency: Direct comparison measures specific surface area: 5-8 minutes per sample

BET surface area: 25 minutes per sample

Repeatability Accuracy:  ≤ ±1 %


原创作者:北京精微高博科学技术有限公司

联系人:张先生(在阿仪网上看到的)

电 话:400-600-5039

手 机:13051666450

Q Q:

传 真:

邮 箱:marketing@jwgb.net

地 址:北京市通州区景盛南二街联东U谷西区10号院10号楼4层